Have a question? Give us a call: 86-13806605444

CD101 Digital Display PID Intelligent Temperature Controller

Short Description:

General description : CD series intelligent (temperature) display regulator adopts 8-bit single-chip high reliability, a variety of sensors freely input, and it adopts a wide range of switching power supply. The product’s performance indicators, input style, control function and the installation size are fully compatible with the i mported intelligent digital temperature controller. CD series intelligent meters, having the latest fuzzy control and combining with advanced PID adjustment...


  • Payment Terms: L/C,D/A,D/P,T/T
  • Product Detail

    Product Tags

    General description :

    CD101  (

    CD series intelligent (temperature) display regulator adopts 8-bit single-chip

    high reliability, a variety of sensors freely input, and it adopts a wide range of

    switching power supply. The product’s performance indicators, input style, control

    function and the installation size are fully compatible with the i mported intelligent

    digital temperature controller. CD series intelligent meters, having the latest fuzzy

    control and combining with advanced PID adjustment algorithm, precisely control

    the controlled objects.

    Size options:

    Models

    External size (W x H x D)

    Hole size

    CD101 □□□-□□*□□-□ 

    48x48x80 (mm)

    45 x 45 (mm)

    CD401 □□□-□□*□□-□ 

    48x96x75 (mm)

    45 x 92 (mm)

    CD701 □□□-□□*□□-□ 

    72x72x75 (mm)

    68 x 68 (mm)

    CD901 □□□-□□*□□-□ 

    96x96x75 (mm)

    92 x 92 (mm)

    Remarks:  the symbol ”□” represents what functions you need, please refer to the following explanation.

     

    Model explanation:

    CD□01 □ □ □- □  □*□  □-□

            ①      ②  ③ ④   ⑤   ⑥ ⑦   ⑧ ⑨

    ①  Standard sizes:  1(48x48x80mm)、4(48x96x75mm)

         7(72x72x75mm)、9(96x96x75mm)

    ②  Control style: F: PID action and automatic calculus(reverse action)

    D: PID action and automatic calculus(positive action)

    ③ Input style:  thermocouple: K, J, R, S, B, E, T, N, W5Re/W26Re, PLII, U, L,

    thermal resistance Pt100, JPt100

    ④ Display range: 

    Input type

    Input display range

    Code

     

    Input type

    Input display range

    Code

    K

    0~200℃

    K 01

     

    S

    0~1600℃

    S 01

    0~400℃

    K 02

     

    0~1769℃

    S 02

    0~600℃

    K 03

     

    B

    400~1800℃

    B 01

    0~800℃

    K 04

     

    0~1820℃

    B 02

    0~1200℃

    K 06

     

    E

    0~800℃

    E 01

    J

    0~200℃

    J 01

     

    0~1000℃

    E 02

    0~400℃

    J 02

     

    J

    -199.90~+649.0℃

    D 01

    0~600℃

    J 03

     

    -199.90~+200.0℃

    D 02

    0~800℃

    J 04

     

    -100.0~+200.0℃

    D 05

    0~1200℃

    J 06

     

    0.0~+200.0℃

    D 08

    R

    0~1600℃

    J 01

     

    0.0~+500.0℃

    D 10

    ⑤  The first control output: (OUT1)(Heating side)

    M: relay contact output    8: Current output(DC4-20mA)

    V: voltage pulse output    G: Thyristor control tube drive with trigger output

    T: Thyristor control tube output

    ⑥  The second control output: (OUT2)(Cooling side)*2

    No mark: when the control action is F or C

    M: relay contact output   8: Current output(DC4-20mA)

    V: voltage pulse output   T: Thyristor control tube output

    ⑦  First alarm(ALAM1)

    N: no alarm        A: Upper limit deviation alarm

    B: Lower limit deviation alarm   C: Upper and lower limit deviation alarm

    W: Lower-limit set alarm value   H: Upper limit output value alarm

    ⑧  Second alarm(ALAM)*2(Same content as the frist alarm)

    J: Lower output value alarm    V: Upper set value alarm

    ⑨  Communication function:

    N: no communication function    5: RS-485(double cable system)


  • Previous:
  • Next:

  • Write your message here and send it to us