PriceList for Incubator Temperature Controller - CJX2-65N New Type AC Contactor – Taiquan Electric
PriceList for Incubator Temperature Controller - CJX2-65N New Type AC Contactor – Taiquan Electric Detail:
General description :
CJX2-DN series AC Contactors are suitable for frequency 50/60Hz, rated insulation voltage up to 1000V, rated operation current 9-150A under AC-3 duty. It is mainly used for making and breaking electric circuits at a long distance & for frequent starting, stopping & controlling AC Motors. It is used in combination with thermal relay to compose a magnetic motor starter. The products comply with IEC60947-4.
Model explanation:
Specifications:
Name |
CJX2-DN (LC1-D New type) AC Contactor |
||||||||||
Model |
CJX2-09N |
CJX2-12N |
CJX2-18N |
CJX2-25N |
CJX2-32N |
||||||
Rated Current (A) | Ie max AC-3(Ue≤440V) |
9 |
12 |
18 |
25 |
32 |
|||||
Ie AC-1(0≤60℃) |
25 |
|
32 |
40 |
50 |
||||||
Number of poles |
3 |
3 |
4 |
3 |
3 |
4 |
3 |
||||
Rated operational power in AC-3(KW) |
220 / 240V |
2.2 |
3 |
4 |
5.5 |
7.5 |
|||||
380 / 400V |
4 |
5.5 |
7.5 |
11 |
15 |
||||||
415 / 440V |
4 |
5.5 |
9 |
11 |
15 |
||||||
500V |
5.5 |
7.5 |
10 |
15 |
18.5 |
||||||
660 / 690V |
5.5 |
7.5 |
10 |
15 |
18.5 |
||||||
1000V |
- |
- |
- |
- |
- |
||||||
Auxiliary contacts | Range comprising up to 4 N/C or N/O instantaneous, up to 1N/O+1N/C time delay and up to 2 N/O or N/C protected contacts and 2 screen continuity terminals | ||||||||||
Compatible manual or auto thermal overload relays | Class 10A | 0.1…10A | 0.10…13A | 0.10…18A | 0.10…32A | 0.10…38A | |||||
Class 20 | 2.5…10A | 2.5…13A | 2.5…18A | 2.5…32A |
– |
||||||
Suppressor modules(d.c. and low consumption contactors have built-in suppression limiting diode as standard) | Varistor |
• |
• |
• |
• |
• |
• |
• |
|||
Diode |
– |
– |
• |
– |
– |
• |
– |
||||
RC circuit |
• |
• |
• |
• |
• |
• |
• |
||||
Bidirectional peak |
• |
• |
• |
• |
• |
• |
• |
||||
Relay |
• |
• |
• |
• |
• |
• |
• |
||||
Interfaces Relay + override function |
• |
• |
• |
• |
•• |
• |
• |
||||
Solid state |
• |
• |
• |
• |
• |
• |
• |
||||
Contactor type references |
~or===3P |
CJX2-09N |
CJX2-12N |
CJX2-18N |
CJX2-25N |
CJX2-32N |
|||||
~4-P |
– |
CJX2-12N |
– |
CJX2-25N |
– |
||||||
===4P |
– |
CJX2-12N |
– |
CJX2-25N |
– |
||||||
Reversing contactor type references
|
~3P |
CJX2-09N |
CJX2-12N |
CJX2-18N |
CJX2-25N |
CJX2-32N |
|||||
===3P |
CJX2-09N |
CJX2-12N |
CJX2-18N |
CJX2-25N |
CJX2-32N |
||||||
~4P |
– |
CJX2-12N |
– |
CJX2-25N |
– |
||||||
===4P |
– |
CJX2-12N |
– |
CJX2-25N |
– |
Name |
CJX2-DN (LC1-D New type) AC Contactor |
|||||||||||
Model |
CJX2-40N |
CJX2-50N |
CJX2-65N |
CJX2-80N |
CJX2-95N |
|||||||
Rated Current (A) | Ie max AC-3(Ue≤440V) |
40 |
50 |
65 |
80 |
95 |
||||||
Ie AC-1(0≤60℃) |
60 |
80 |
|
125 |
||||||||
Number of poles |
3 |
4 |
3 |
3 |
4 |
3 |
4 |
3 |
||||
Rated operational power in AC-3(KW) |
220/240v |
11 |
15 |
18.5 |
22 |
25 |
||||||
380/400v |
18.5 |
22 |
30 |
37 |
45 |
|||||||
415/440V |
22 |
25 / 30 |
37 |
45 |
45 |
|||||||
500v |
22 |
30 |
37 |
55 |
55 |
|||||||
660/690v |
30 |
33 |
37 |
45 |
45 |
|||||||
1000 |
22 |
30 |
37 |
45 |
45 |
|||||||
Auxiliary contacts | Range comprising up to 4 N/C or N/O instantaneous, up to 1N/O+1N/C time delay and up to 2 N/O or N/C protected contacts and 2 screen continuity terminals | |||||||||||
Compatible manual or auto thermal overload relays | Class 10A | 17…50A | 17…70A | 17…80A | 17…104A | 17…104A | ||||||
Class 20 | 17…40A | 17…65A | 17…70A | 17…80A |
|
|||||||
Suppressor modules(d.c. and low consumption contactors have built-in suppression limiting diode as standard) | Varistor |
• |
• |
• |
|
• |
• |
• |
• |
• |
||
Diode |
• |
• |
• |
|
• |
• |
• |
• |
• |
|||
RC circuit |
• |
• |
• |
|
• |
• |
• |
• |
• |
|||
Bidirectional peak |
• |
• |
• |
|
• |
• |
• |
• |
• |
|||
Relay |
• |
• |
• |
• |
• |
• |
• |
• |
• |
|||
Interfaces Relay + override function |
• |
• |
• |
• |
• |
• |
•• |
• |
• |
|||
Solid state |
• |
• |
• |
• |
• |
• |
• |
• |
• |
|||
Contactor type references |
~or===3P |
CJX2-40N |
CJX2-50N |
CJX2-65N |
CJX2-80N |
CJX2-95N |
||||||
~4-P |
CJX2-40N |
– |
CJX2-65N |
CJX2-80N |
– |
|||||||
===4P |
CJX2-40N |
– |
CJX2-65N |
CJX2-80N |
– |
|||||||
Reversing contactor type references
|
~3P |
CJX2-40N |
CJX2-50N |
CJX2-65N |
CJX2-80N |
CJX2-95N |
||||||
===3P |
– |
– |
– |
– |
– |
|||||||
~4P |
CJX2-40N |
– |
CJX2-65N |
CJX2-80N |
– |
|||||||
===4P |
– |
– |
– |
– |
– |
Standard Control Circuit Voltages
Coil Volts (V) |
24 |
42 |
48 |
110 |
220 |
230 |
240 |
380 |
400 |
415 |
440 |
500 |
660 |
50Hz |
B5 |
D5 |
E5 |
F5 |
M5 |
P5 |
U5 |
Q5 |
V5 |
N5 |
R5 |
S5 |
Y5 |
60HZ |
B6 |
D6 |
E6 |
F6 |
M6 |
- |
U6 |
Q6 |
- |
- |
R6 |
- |
- |
50/60Hz |
B7 |
D7 |
E7 |
F7 |
M7 |
P7 |
U7 |
Q7 |
V7 |
N7 |
R7 |
- |
- |
Product detail pictures:



Related Product Guide:
Global Irrigation Timers and Controllers Market 2018-2022 | Growth Analysis and Forecast | Technavio | Pid Temperature Controller
3 Ways to Automate Your Home Cannabis Grow | Switching Capacitance Ac Contactor
With advanced technologies and facilities, strict high-quality handle, reasonable rate, superior services and close co-operation with prospects, we are devoted to furnishing the best price for our customers for PriceList for Incubator Temperature Controller - CJX2-65N New Type AC Contactor – Taiquan Electric , The product will supply to all over the world, such as: Brunei , Israel , Tanzania , We welcome you to visit our company & factory and our showroom displays various products that will meet your expectations. Meanwhile, it is convenient to visit our website. Our sales staff will try their best to provide you with the best services. If you need more information, please do not hesitate to contact us via E-mail, fax or telephone.

The sales manager is very patient, we communicated about three days before we decided to cooperate, finally, we are very satisfied with this cooperation!
